#70 FILTER 1 M 3 2 200 On XAP 400 unit 0 (#70) the filter (FILTER) for mic
(M) channel 1, node 3 is set as a low-pass filter (2) at 200Hz.

#71 FILTER B P 2 4 3000 -10 On XAP 400 unit 1 (#71) the filter (FILTER) for
processing (P) channel B, node 2, is set as a low shelving (4) filter at 3000Hz and a
gain of -10dB.

#72 FILTER 3 M 2 6 5000 -15 1.00 On XAP 400 unit 2 (#72), the filter
(FILTER) for mic (M) channel 3, node 2, is set as a PEQ (6) with a center frequency
of 5000Hz, a bandwidth of 1.00, and a gain of -15dB.

#73 FILTER B P 2 7 4000 On XAP 400 unit 3 (#73), the filter (FILTER) for
processing (P) channel B, node 2, is set as a CD Horn (7) at a frequency of 4000Hz.

FILTSEL - Filter Select

This command turns on and off the filters on input and audio processing channels.
Command form: DEVICE FILTSEL [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

FILTSEL

Command form

Channel

See Groups and Channels, page 105

Group

M = Mic Inputs, P = Processing Channels

Node

1-4, or * for all (selects mic input filter)

1-15, or * for all (selects processing channel filter)

Value

0 = Off, 1 = On, 2 = Toggle, Null to return current state

Example:

#74 FILTSEL B P 2 1 On XAP 400 unit 4 (#74), the filter

(FILTSEL) on processing (P) channel B, node 2, is set to on (1).

FLOW - Flow Control

This command selects/reports the flow control of the serial port on the unit.
Hardware flow control is implemented using DTR and DSR.
Command form: DEVICE FLOW [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

FLOW

Command form

Value

0 = Off, 1 = On, 2 = Toggle, Null to return current state

Example:

#76 FLOW 1 On XAP 400 unit 6 (#76), the flow control (FLOW) to