COUNTRY — Country Selection

This command sets/reports the country for compliance.
Command form: DEVICE COUNTRY [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

COUNTRY

Command form

Value

1 = US/Canada, 2 = Europe (CTR21), 3 = Mexico
4 = Australia, 5 = South Africa, 6 = Japan
7 = Brazil, Null to return current state

Example:

#70 COUNTRY 1 On the XAP 400 unit 0 (#70), the country selection

(COUNTRY) is set to US/Canada (1).

DECAY - Decay Adjust

This command selects/reports the setting of the decay rate for a specified input.
Command form: DEVICE DECAY [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

DECAY

Command form

Channel

Range 1—4 (selects mic input)

Value

1 = Slow, 2 = Medium, 3 = Fast, Null to return current state

Example:

#73 DECAY 1 3 On XAP 400 unit 3 (#73), the decay rate (DECAY)

for mic channel 1 is set to fast (3).

DELAY - Delay Adjust

This command selects/reports the delay time of each assignable processing channel.
Command form: DEVICE DELAY [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

DELAY

Command form

Channel

A—D (select processing channel)

Value

0.00 to 250 (selects delay)

ms

Null to return current state

Example:

#76 DELAY A 200 On XAP 400 unit 6 (#76) the delay (DELAY) for

processing channel A is set to 200ms.