beautypg.com

Alc - automatic level control, Amblvl - ambient level adjust, Baud - baud rate – ClearOne XAP400 User Manual

Page 118: Appendices ~ appendix e: serial commands, Argument details

background image

112

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

ALC - Automatic Level Control

This command selects/reports the state of the automatic level control.
Command form: DEVICE ALC [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

ALC

Command form

Channel

See Group and Channels, page 105

Group

17 (R)

Value

0 = Off, 1 = On, 2 = Toggle, Null to query in text

Example:

#72 ALC 1 1 On XAP 400 unit 2 (#72), the automatic level control

(ALC) for the hybrid (1) is on (1).

AMBLVL - Ambient Level Adjust

This command selects/reports the setting of the ambient level.

Command form: DEVICE AMBLVL [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

AMBLVL

Command form

Channel

Range 1—4 (selects input channel)

Value

-80.0 to 0 (sets ambient level in dB), Null to return current level

Example:

#73 AMBLVL 1 -30 On XAP 400 unit 3 (#73), the ambient level

(AMBLVL) for mic input 1 is set to -30dB.

BAUD - Baud Rate

This command selects/reports the baud rate of the serial port.
Command form: DEVICE BAUD [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

BAUD

Command form

Value

9600, 19200, 38400, 57600
(Null to query in text)

Example:

#76 BAUD 38400 On XAP 400 unit 6 (#76), the baud rate (BAUD)

for the RS-232 port is set to 38,400 (38400).