Alc - automatic level control, Amblvl - ambient level adjust, Baud - baud rate – ClearOne XAP400 User Manual
Page 118: Appendices ~ appendix e: serial commands, Argument details
112
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
ALC - Automatic Level Control
This command selects/reports the state of the automatic level control.
Command form: DEVICE ALC
Argument details
Name
Description
Device
0—7 or * to select all units
ALC
Command form
Channel
See Group and Channels, page 105
Group
17 (R)
Value
0 = Off, 1 = On, 2 = Toggle, Null to query in text
Example:
#72 ALC 1 1 On XAP 400 unit 2 (#72), the automatic level control
(ALC) for the hybrid (1) is on (1).
AMBLVL - Ambient Level Adjust
This command selects/reports the setting of the ambient level.
Command form: DEVICE AMBLVL
Argument details
Name
Description
Device
0—7 or * to select all units
AMBLVL
Command form
Channel
Range 1—4 (selects input channel)
Value
-80.0 to 0 (sets ambient level in dB), Null to return current level
Example:
#73 AMBLVL 1 -30 On XAP 400 unit 3 (#73), the ambient level
(AMBLVL) for mic input 1 is set to -30dB.
BAUD - Baud Rate
This command selects/reports the baud rate of the serial port.
Command form: DEVICE BAUD [Value]
Argument details
Name
Description
Device
0—7 or * to select all units
BAUD
Command form
Value
9600, 19200, 38400, 57600
(Null to query in text)
Example:
#76 BAUD 38400 On XAP 400 unit 6 (#76), the baud rate (BAUD)
for the RS-232 port is set to 38,400 (38400).