MINIT - Modem Initialization String

This command sets/reports the modem initialization string of the serial port when in
modem mode.

Command form: DEVICE MINIT [String]

Argument details

Name

Description

Device

0—7 or * to select all units

MINIT

Command form

String

1-80 characters (select string characters to be sent to the modem
when the unit is initialized
CLEAR = clears the modem initialization string
Null = Current string

Example:

#76 MINIT ATZ On XAP 400 unit 6 (#76), the modem initialization

string (MINIT) is ATZ.

MINMAX - Minimum and Maximum Gain Setting

This command changes or reports back the minimum and maximum gain setting for
an input, output or assignable processing block.

Command form: DEVICE MINMAX [Minimum] [Maximum]

Argument details

Name

Description

Device

0—7 or * to select all units

MINMAX

Command form

Channel

See Groups and Channels

Group

I, O, M, P, L

Minimum

-65.00 to 20.00, Null to return current settings

Maximum

-65.00 — 20.00

Example:

#75 MINMAX 2 M -12 10 On XAP 400 unit 5 (#75), the minimum

and maximum (MINMAX) relative gain settings for mic (M) channel 2 are -12dB
and 10dB respectively.