MINIT - Modem Initialization String
This command sets/reports the modem initialization string of the serial port when in
modem mode.
Command form: DEVICE MINIT [String]
Argument details
Name
Description
Device
0—7 or * to select all units
MINIT
Command form
String
1-80 characters (select string characters to be sent to the modem
when the unit is initialized
CLEAR = clears the modem initialization string
Null = Current string
Example:
#76 MINIT ATZ On XAP 400 unit 6 (#76), the modem initialization
string (MINIT) is ATZ.
MINMAX - Minimum and Maximum Gain Setting
This command changes or reports back the minimum and maximum gain setting for
an input, output or assignable processing block.
Command form: DEVICE MINMAX
Argument details
Name
Description
Device
0—7 or * to select all units
MINMAX
Command form
Channel
See Groups and Channels
Group
I, O, M, P, L
Minimum
-65.00 to 20.00, Null to return current settings
Maximum
-65.00 — 20.00
Example:
#75 MINMAX 2 M -12 10 On XAP 400 unit 5 (#75), the minimum
and maximum (MINMAX) relative gain settings for mic (M) channel 2 are -12dB