Gate Ratio

Gate Ratio specifies how much louder the audio level must be above the ambient
level before the channel gates on. The gate ratio range is from 0 to 50dB. Default is
15dB.

Hold Time

Hold Time determines how long the channel stays gated on after the audio is below
the threshold. The hold time range is from .1 to 8.0 seconds. Default is .3 seconds.

Off Attenuation

Off Attenuation sets the amount of level reduction applied to a channel when it is
gated off. The range is from 0 to 50dB. Default is 12dB.

Ambient Level

Ambient Level is available only if the Adaptive Ambient feature isn’t enabled. Use
Ambient Level if you want to specify a fixed reference point rather than one that
adjusts for background noise. The range is from -80 to 0dB. Default is Off.

Decay Rate

Decay Rate determines how fast a channel gates off after the hold time expires.
Default is Medium.

Figure 3.36. XAP 400 automixing gate functions