Lvlreport - level report, Lvlrrate - level report rate, Appendices ~ appendix e: serial commands – ClearOne XAP400 User Manual
Page 133: Argument details
127
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
LVLREPORT - Level Report
This command selects level status reporting.
Command form: DEVICE LVLREPORT
Argument details
Name
Description
Device
0—7 or * to select all units
LVLREPORT
Command form
Channel
See Groups and Channels, page 105
Group
See Groups and Channels, page 105
Position
See Meter Type Definitions, page 106
Value
0 = Off (Delete level from list of levels to be reported)
1 =On (Add specified level to list of levels to be reported)
2 = Toggle
Example:
#72 LVLREPORT 8 L I 1 On XAP 400 unit 2 (#72), the level
(LVLREPORT) of line level (L) input 8 at the input stage (I) is to be added (1) to
the report.
LVLRRATE - Level Report Rate
Sets the level report rate for the unit and activates/deactivates level repeating.
Command form: DEVICE LVLRRATE [Value]
Argument details
Name
Description
Units
Device
0—7 or * to select all units
LVLRRATE
Command form
Value
0 = Turn off reporting but leave current list
1 = Turn off reporting and clear the list
50 to 1000 = Set Rate (1 meter every x ms) ms
Null to return current value
Example:
#73 LVLRRATE 100 On XAP 400 unit 3 (#73), the level report rate
(LVLRRATE) is set to 100ms.