RAMP — Ramp Gain Adjustment
This command starts/stops the gain ramp for an input, output, or assignable
processing block. There is no query for this command.
Command form: DEVICE RAMP
Argument details
Name
Description
Unit
Device
0—7 or * to select all units
RAMP
Command
Channel
See Groups and Channels, page 105
Group
I, O, M, L, P, T, R (1, 2, 3, 5, 16, 17)
Rate
-50 to 50
dB/s
If value = 0. the ramp will stop
If value < 0, the gain will ramp down
If value > 0, the gain will ramp up
Target
-65 to 20
dB
If null in text, the ramp will use the
channel’s maximum and minimum for a target
Example:
#77 RAMP 5 L 6 12
On XAP 400 unit 7 (
#77
), the gain (
RAMP
)
on
L
ine Input
5
will increase at a rate of
6d
B/sec until the
12
dB point is
reached.
REDIAL — Dial the last number again
This command redials the last number. There is no query for this command.
Command form: DEVICE REDIAL
Argument details
Name
Description
Device
0—7 or * to select all units
REDIAL
Command
Channel
See Groups and Channels, page 105
Example: #70 REDIAL 1
On XAP 400 unit 0 (#70), the hybrid (1) will
REDIAL the last phone number dialed.