beautypg.com

Ghold- gate hold time adjust, Gmode - gating mode, Gover - gating override – ClearOne XAP400 User Manual

Page 128: Appendices ~ appendix e: serial commands, Argument details

background image

122

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

GHOLD- Gate Hold Time Adjust

This command selects/reports the setting of hold time.
Command form: DEVICE GHOLD [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

GHOLD

Command form

Channel

See Groups and Channels, page 105

Value

0.10-8.00

S

Null to return the current hold time

Example:

#70 GHOLD 1 .3 On XAP 400 unit 0 (#70), the hold time (GHOLD)

for mic channel 1 is 300ms (.3).

GMODE - Gating Mode

This command selects/reports the setting of gating mode.
Command form: DEVICE GMODE [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

GMODE

Command form

Channel

1—4 (select mic input)

Value

1 = auto, 2 = manual on, 3 = manual off, Null= current mode

Example:

#75 GMODE 1 2 On XAP 400 unit 5 (#75), mic channel 1 is set to a

gating mode (GMODE) if manual on (2).

GOVER - Gating Override

This command selects/reports the setting of gating override.
Command form: DEVICE GOVER [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

GOVER

Command form

Channel

1—4 (select mic input)

Value

0 = Off, 1 = On, 2 = Toggle, Null = current mode

Example:

#76 GOVER 1 0 On XAP 400 unit 6 (#76), the gating override

(GOVER) on mic channel 1 is set to off (0).