Ringer - audible ring selection, Ringerlvl - audible ring level, Rxboost - receive boost – ClearOne XAP400 User Manual
Page 145: Appendices ~ appendix e: serial commands, Argument details

139
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
RINGER - Audible Ring Selection
This command sends/reports the use of an audible ring.
Command form: DEVICE RINGER
Argument details
Name
Description
Device
0—7 or * to select all units
RINGER
Command
Channel
See Groups and Channels, page 105
Value
0 = Off, 1 = On, 2 = Toggle, Null = Current state
Example:
#72 RINGER 11 On XAP 400 unit 2 (#72), the audible RINGER
indication for the hybrid (1) is on (1).
RINGERLVL - Audible Ring Level
This command selects/reports the audible ring level.
Command form: DEVICE RINGERLVL
Argument details
Name
Description
Units
Device
0—7 or * to select all units
RINGERLVL
Command
Channel
See Groups and Channels, page 105
Value
-12.00 — 12.00
dB
(Null to query in text)
Example:
#73 RINGERLVL 13 On XAP 400 unit 3 (#73), the audible ringer
level (RINGERLVL) for the hybrid (1) is 3dB.
RXBOOST - Receive Boost
This command selects/reports the receive boost status.
Command form: DEVICE RXBOOST
Argument details
Name
Description
Units
Device
0—7 or * to select all units
RXBOOST
Command
Channel
See Groups and Channels, page 105
Value
0, 3, 6, 9, 12
dB
Null to return current state
Example:
#74 RXBOOST 1 6 On XAP 400 unit 4 (#74), the receive boost
(RXBOOST) of the hybrid (1) is set to 6dB.