RINGER - Audible Ring Selection

This command sends/reports the use of an audible ring.
Command form: DEVICE RINGER [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

RINGER

Command

Channel

See Groups and Channels, page 105

Value

0 = Off, 1 = On, 2 = Toggle, Null = Current state

Example:

#72 RINGER 11 On XAP 400 unit 2 (#72), the audible RINGER

indication for the hybrid (1) is on (1).

RINGERLVL - Audible Ring Level

This command selects/reports the audible ring level.
Command form: DEVICE RINGERLVL [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

RINGERLVL

Command

Channel

See Groups and Channels, page 105

Value

-12.00 — 12.00

dB

(Null to query in text)

Example:

#73 RINGERLVL 13 On XAP 400 unit 3 (#73), the audible ringer

level (RINGERLVL) for the hybrid (1) is 3dB.

RXBOOST - Receive Boost

This command selects/reports the receive boost status.
Command form: DEVICE RXBOOST [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

RXBOOST

Command

Channel

See Groups and Channels, page 105

Value

0, 3, 6, 9, 12

dB

Null to return current state

Example:

#74 RXBOOST 1 6 On XAP 400 unit 4 (#74), the receive boost

(RXBOOST) of the hybrid (1) is set to 6dB.