Aconnlvl - audible connect/disconnect level, Ad - auto-disconnect enable/ disable, Aec - acoustic echo canceller enable/disable – ClearOne XAP400 User Manual
Page 116: Appendices ~ appendix e: serial commands, Argument details
110
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
ACONNLVL - Audible Connect/Disconnect Level
This command selects/reports the audible connect / disconnect indicator’s level.
Command form: DEVICE ACONNLVL
Argument details
Name
Description
Units
Device
0—7 or * to select all units
ACCONNLVL
Command form
Channel
See Groups and Channels on page 105
Value
-12.00—12.00
dB
Null to query in text
Example:
#71 ACONNLVL 1 -6 On XAP 400 unit 1 (#71), audible connect/
disconnect level (ACONNLVL) on channel 1 is set to -6dB.
AD - Auto-Disconnect Enable/ Disable
This command selects/reports the setting of auto-disconnect.
Command form: DEVICE AD
Argument details
Name
Description
Device
0—7 or * to select all units
AD
Command form
Channel
See Groups and Channels on page 105
Value
0 = Off, 1 = Loop Drop, 2 = Call Progress,
3 = Loop Drop + Call Progress, Null to query in text
Example:
#70 AD 1 3 On XAP 400 unit 0 (#70), auto-disconnect (AD) on
channel 1 (1) is set to Loop Drop + Call Progress (3).
AEC - Acoustic Echo Canceller Enable/Disable
This command selects/reports the setting of acoustic echo canceller.
Command form: DEVICE AEC
Argument details
Name
Description
Device
0—7 or * to select all units
AEC
Command form
Channel
Range 1—4 (selects input)
Group
M (selects mic group)
Value
0 = Off, 1 = On, 2 = Toggle, Null to query in text
Example:
#70 AEC 1 0 On XAP 400 unit 0 (#70) the echo canceller (AEC) for
mic channel 1 (1) is set to off (0).