Fmp - first mic priority mode, Fpp - front panel passcode, Appendices ~ appendix e: serial commands – ClearOne XAP400 User Manual
Page 126: Argument details, Button assignment
120
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
FMP - First Mic Priority Mode
This command selects/reports first Mic priority mode for a gating group.
Command form: DEVICE
FMP
Argument details
Name
Description
Device
0—7 or * to select all units
FMP
Command form
Channel
1—4 (selects mic inputs), A—D (selects gating group)
Value
0 = Off, 1 = On, 2 = Toggle, Null returns the current mode
Example:
#75 FMP A 1 On XAP 400 unit 5 (#75), the first mic priority mode
(FMP) for gating group A is set to on (1).
FPP - Front Panel Passcode
This command sets and reports the current passcode setting for the unit. Each
character in the password represents a button on the front panel. See button
assignment table below. When the user is requested to unlock the front panel, they
must press the buttons in the sequence of the stored password.
Command form: DEVICE FPP
Button assignment
Value Button represented
1
Up arrow button
2
Enter button
3
ESC button
4
Down arrow button
5
Meter button
Argument details
Name
Description
Device
0—7 or * to select all units
FPP
Command form
Char 1—5
1—5 (see button assignments)
CLEAR will clear the passcode
Null will return current passcode
Example:
#75 FPP 12345 On XAP 400 unit 5 (#75), the front panel passcode