Appendix g: complianc, Appendix g: compliance, Tout - time out select – ClearOne XAP400 User Manual
Page 151: Uid - unit id, Ver - version, Appendices ~ appendix e: serial commands, Argument details
145
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
TOUT - Time Out Select
This command selects/reports the inactivity time out before returning to the unit title
screen.
Command form: DEVICE TOUT [Value]
Argument details
Name
Description
Device
0—7 or * to select all units
TOUT
Command
Value
0 = Off, 1—15 (select time out in minutes)
Null = Current mode
Example:
#72 TOUT 5 On XAP 400 unit 2 (#72), the front panel of the unit will
time out (TOUT) after 5 minutes.
UID - Unit ID
This command reports the unit ID. This command is read only.
Command form: DEVICE UID [Value]
Argument details
Name
Description
Units
Device
0—7 or * to select all units
UID
Command
Value
Null to return value
Hexadecimal
Example:
#73 UID B465F991 The unit ID number (UID) received from XAP 400
unit 3 (#73), is B456F991.
VER - Version
This command reports the firmware version of the unit. This command is read only.
Command form: DEVICE VER [Value]
Argument details
Name
Description
Device
0—7 or * to select all units
VER
Command
Value
Null to return value
Example:
#74 VER 1.0.0 The version of the firmware (VER) programmed into
XAP 400 unit 4 (#74), is 1.0.0.