beautypg.com

Appendix g: complianc, Appendix g: compliance, Tout - time out select – ClearOne XAP400 User Manual

Page 151: Uid - unit id, Ver - version, Appendices ~ appendix e: serial commands, Argument details

background image

145

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendices

~ Appendix E: Serial Commands

TOUT - Time Out Select

This command selects/reports the inactivity time out before returning to the unit title
screen.
Command form: DEVICE TOUT [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

TOUT

Command

Value

0 = Off, 1—15 (select time out in minutes)
Null = Current mode

Example:

#72 TOUT 5 On XAP 400 unit 2 (#72), the front panel of the unit will

time out (TOUT) after 5 minutes.

UID - Unit ID

This command reports the unit ID. This command is read only.
Command form: DEVICE UID [Value]

Argument details

Name

Description

Units

Device

0—7 or * to select all units

UID

Command

Value

Null to return value

Hexadecimal

Example:

#73 UID B465F991 The unit ID number (UID) received from XAP 400

unit 3 (#73), is B456F991.

VER - Version

This command reports the firmware version of the unit. This command is read only.
Command form: DEVICE VER [Value]

Argument details

Name

Description

Device

0—7 or * to select all units

VER

Command

Value

Null to return value

Example:

#74 VER 1.0.0 The version of the firmware (VER) programmed into

XAP 400 unit 4 (#74), is 1.0.0.