Xap 400 serial commands, Appendices ~ appendix e: serial commands – ClearOne XAP400 User Manual
Page 113
107
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
XAP 400 Serial commands
Command
Function
AA
Sets auto-answer for a telco channel
AAMB
Selects/reports adapt ambient setting
ACONN
Sets the audible connect signal to on/off
ACONNLVL
Sets the level of the audible connect signal
AD
Sets auto-disconnect for a telco channel
AEC
Selects/reports acoustic echo canceller setting
AGC
Enable/disables AGC
AGCSET
Selects/reports AGC settings on inputs
ALC
Sets the ALC for the telco receive
AMBLVL
Selects/reports ambient level
BAUD
Selects/reports the baud rate of the serial port
CGROUP
Selects/reports compressor group setting
CHAIRO
Selects/reports chairman override setting
COMPRESS
Sets/reports compressor on audio processing
channel
COMPSEL
Selects/reports compressor activity for
processor
COUNTRY
Sets/reports the country for compliance
DECAY
Sets/reports decay rate
DELAY
Sets/reports delay rate
DELAYSEL
Selects/reports processor channel delay
DFLTM
Sets/reports default meter
DIAL
Dials a DTMF sequence or reports last
sequence dialed
DID
Selects/reports device ID
DSPVER
Reports DSP firmware version
DTMFLVL
Sets the DTMF tone level in the room
DTONELVL
Selects/reports the audible dial tone level
FILTER
Selects/reports input/processor channel filter
setting
FILTSEL
Enables/disables filters on input/processor
channel
FLOW
Selects/reports the flow control of the serial
port
FMP
Sets/reports 1st Mic Priority for mic gating
group
FPP
Sets/reports current passcode setting
GAIN
Changes/reports gain for in, out, or process.
Command
Function
GATE
Reports gate status of channels 1—4
GHOLD
Selects/reports hold time setting
GMODE
Selects/reports gating mode setting
GOVER
Selects/reports gating override setting
GRATIO
Selects/reports gate ratio setting
GREPORT
Selects/reports gate status report frequency
GRPSEL
Selects/reports input gating group assignments
HOOK
Sends a hook flash to the telephone line
HOOKD
Sets hook flash duration
LABEL
Selects/reports label of specified channel
LFP
Sets/reports status of front panel access
LOCK
Selects/reports the state of the preset and
macro lock. When on, the lock prevents presets
and macros that have been flagged from being
altered in any way.
LOCKPRST
Selects/reports whether the lock is applied to a
preset or macro. If a preset or macro has the
lock applied, it can only be changed if the unit
is unlocked with the password.
LOCKPWD
Selects/reports the password for the
preset/macro lock. This can only be changed if
the unit is unlocked.
LMO
Selects/reports Last Mic On mode
LVL
Reports in, out, or processor level
LVLREPORT Selects/reports level status
LVLRRATE
Sets the level report rate for the unit
MACRO
Executes macro or reports last macro
executed
MASTER
Reports the mode of the unit
MAX
Changes/reports max gain setting for in, out,
processor block
MDMODE
Enables/disables the modem mode for the unit
MIN
Changes/reports minimum gain setting for in,
out, processor block
MINIT
Sets/reports modem initialization string of
serial port
MINMAX
Changes/reports min and max gain from in,
out, processor block
Appendices
~ Appendix E: Serial Commands