ClearOne Converge Pro User Manual
Page 309
304
RXBSTEN – Receive Boost Enable
This command selects/reports the receive boost status.
Command Form
: DEVICE RXBSTEN
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
SERECHO – Serial Echo
This command selects/reports the serial echo of the RS-232 port.
Command Form
: DEVICE SERECHO [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
NOTE: The unit will return the updated state of the last selection in the same form as the
command.
SFTYMUTE – Safety Mute
This command selects/reports the state of the safety mute. Safety mute holds all outputs in a muted state. It used
for syncing to a site document to avoid feedback or blown speakers until the unit is in a settled state.
Command Form: DEVICE SFTYMUTE [Value]
Argument Type
Size
Values
Units
Value
Channel
4
0 = off
1 = on
2 = toggle
(Null to query in text)
-
SIGGEN – Signal Generator
This command selects/reports of the signal generator activation.
Command Form
: DEVICE SIGGEN [Channel Group Type Amplitude Frequency]
Argument
Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
(Null to query in text)
-
Group
Group
1
1, 3, 7 (I, M, L)
-
Type
Unsigned Integer
2
1 = Pink Noise
2 = White Noise
3 = Tone
-
Amplitude
Signed Float
4
-60.00 – 20.00
dB
Frequency
Unsigned Float
4
Type 1 – 2
0 (Null in text)
Hz
Type 3
20.00 – 20000.00
SIGGENEN – Signal Generator Enable
This command selects/reports of the signal generator activation.
Command Form
: DEVICE SIGGENEN [Value]
Argument
Type
Size
Values
Units
Value
Unsigned Integer
4
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-