AVG – Adaptive Volume Gain
This command sets the maximum gain setting that the algorithm will not exceed.
Command Form
:
Argument Type
Size
Values
Units
Channel
Channel
1
See GroupsAndChannels
-
Group
Group
1
23 (J)
-
Value
Signed Short
2
0.00 to +18.00
(Null to query in text)
dB
AVR – Adaptive Volume Reference
This command selects/reports the microphone or expansion bus reference channel to be used for adaptive
volume tracking on a power amplifier channel.
Command Form
: DEVICE AVR [CHANNEL] [GROUP]
Argument Type
Size
Values
Units
Channel
Channel
1
(M) 1-8
(E) 1-18
(Null to query in text)
-
Group
Group
1
3, 6 (M or E)
-
AVRT – Adaptive Volume Ratio
This command sets the ratio at which gain will be automatically applied based upon the ambient level in the
reference microphone. Example: A 1:1 setting would apply 1 dB of gain for every 1dB rise in ambient level of the
reference microphone up to the Max Gain setting.
Command Form
: DEVICE AVRT
Argument Type
Size
Values
Units
Channel
Channel
1
See GroupAndChannels
-
Group
Group
1
23 (J)
-
Value
Unsigned Short
2
0 = 2:1
1 = 1:1
2 = 1:2
(Null to query in text)
Ratio
AVT – Adaptive Volume Threshold
This command sets the level at which the adaptive volume algorithm will be activated. This value is referenced to
the noise floor of the channel and the target above ambient for the adaptive volume to reach.
Command Form
:
Device AVT
Argument Type
Size
Values
Units
Channel
Channel
1
See GroupAndChannels
-
Group
Group
1
23 (J)
-
Value
Signed Short
2
-80.00 to 0.00
(Null to query in text)
-
BAUD – Baud Rate
This command selects/reports the baud rate of the serial port.
Command Form
: DEVICE BAUD [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
9600, 19200, 38400, 57600, 115200
(Null to query in text)
-