ClearOne Converge Pro User Manual
Page 297
292
MUTE – Mute
This command selects/reports the setting of mute on a channel.
Command Form
: DEVICE MUTE
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F,
T, R, K, Z, D, U, V)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
NAME – Unit Name (NETBIOS Name)
This command sets/reports the name of the unit which is also used for its NETBIOS name.
Command Form
: DEVICE NAME [Value]
Argument Type
Size
Values
Units
Value
String
16
1 – 15 Characters
(Null to query in text)
-
NCD – Noise Cancellation Depth Adjust
This command selects/reports the depth setting of the Noise Cancellation.
Command Form
: DEVICE NCD
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
3, 17, 26 (M, R, Z, V)
-
Value
Unsigned Integer
2
6 – 15
(Null to query in text)
dB
NCSEL – Noise Cancellation Select
This command selects/reports the setting of the Noise Cancellation for each microphone channel.
Command Form
: DEVICE NCSEL
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
3, 17, 26 (M, R, Z, V)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
NLP – Non Linear Processing Adjust
This command selects/reports the setting of non-linear processing for each microphone channel.
Command Form
: DEVICE NLP
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
3 (M)
-
Value
Unsigned Integer
2
0 = Off
1 = Soft
2 = Medium
3 = Aggressive
(Null to query in text)
-