ClearOne Converge Pro User Manual
Page 262
![background image](/manuals/598135/262/background.png)
257
SERIAL COMMANDS
Serial commands are shown in bold, followed by the command form and argument details.
AA – Auto Answer Enable / Disable
This command selects/reports the setting of auto answer.
Command Form
: DEVICE AA
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
AAMB – Adaptive Ambient Mode
This command selects/reports the setting of adaptive ambient.
Command Form
: DEVICE AAMB
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
3 (M)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = toggle
(Null to query in text)
-
AARINGS – Number of Rings to Auto Answer On
This command selects/reports the setting of the number of rings to auto answer.
Command Form
: DEVICE AARINGS
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned Integer
2
2 - 4
(Null to query in text)
-
ACONN – Audible Connect / Disconnect Indication
This command selects/reports the status of the audible connect / disconnect indication.
Command Form
: DEVICE ACONN
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-