GATE – Gate Status
This command reports the gate status of Mics. This command is read only.
Command Form
: DEVICE GATE [Value]
Argument
Type
Size
Values
Units
Value
Hexadecimal
4
Bits 0 – 7 represent gate status on Mics 1 – 8
(Null sent in text, Value returned)
-
GHOLD – Gate Hold Time Adjust
This command selects/reports the setting of hold time.
Command Form
: DEVICE GHOLD
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
3 (M)
-
Value
Unsigned Float
2
0.10 – 8.00
(Null to query in text)
S
GMODE – Gating Mode
This command selects/reports the setting of gating mode.
Command Form
: DEVICE GMODE
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
3 (M)
-
Value
Unsigned Integer
2
1 = Auto
2 = Manual On
3 = Manual Off
(Null to query in text)
-
GOVER – Gating Override
This command selects/reports the setting of gating override.
Command Form
: DEVICE GOVER
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
3 (M)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
GPIOSTATUS – General Purpose Status
This command sets the state of a General Purpose Status Pin.
Command Form
: DEVICE GPIOSTATUS Pin Port [Value]
Argument Type
Size
Values
Units
Pin
Unsigned
Integer
1
1 – 24 (Only user definable status pins.
-
Port
Unsigned
Integer
1
1 – 2
-
Value
Unsigned
Integer
2
0 = High
1 = Low
2 = Toggle
(NULL to query in text)
-