270
CNETVER – CobraNet Tx Board F/W Version
This command reports the firmware version of the CobraNet board. This command is Query ONLY.
Command Form
: DEVICE CNETVER [Value]
Argument
Type
Size
Values
Units
CNetVersion String
12
Version format “MM.mm.rr.ee”
(NULL terminated –
Major.Minor.Revision.Enineering)
-
COMPDLY – Compressor Delay
This command sets signal compression delay on a Channel for look ahead compression functionality. Delay from
0-20 msec.
Command Form
: DEVICE COMPDLY
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Unsigned Integer
2
0 - 20
(Null to query in text)
msec
COMPDLYEN – Compressor Delay Enable
This command enables signal compression delay on a Channel for look-ahead compression functionality
Command Form
: DEVICE COMPDLYEN
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Unsigned Short
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
COMPERSIST – CobraNet Persistence
This command sets/reports the CobraNet Persistence for the CONNECT CobraNet board.
Command Form
: DEVICE COMPERSIST [Value]
Argument Type
Size
Values
Units
Value
Integer
4
0 - 255 (Default = 32)
(Null to query in text)
-
COMPRESS – Compressor Adjust
This command selects/reports the settings of the compressor.
Command Form
: DEVICE COMPRESS
Argument
Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
-
Group
Group
1
5 (P)
-
Threshold
Signed Integer
1
-60 – 20
(Null to query in text)
dB
Ratio
Unsigned Integer
1
1 – 20
Attack
Unsigned Float
2
0.00 – 100.00
Ms
Release
Unsigned Integer
2
100 – 2000
Ms
Gain
Unsigned Float
4
0.00 – 20.00
dB