The data type for a OCI data item determines how the data is
returned from the control to the OCI. You define variables according
to this data type. Requesting the wrong data type for a data item to
the control can return invalid data or an error. Valid data types
include:
DATA TYPE:
Description:
STRING
Alphanumeric string ranging from 0 to 65,535 characters
INT
Whole number ranging from -32,768 to 32,767
UINT
Unsigned integer
DINT
Double integer
UDINT
Unsigned double integer
LINT
Long Integer
SINT
Signed integer
USINT
Unsigned single integer
REAL
Real number
LREAL
Long Real
BOOL
Boolean (True/False)
R indicates the data is read only (passed from CNC to OCI). W
indicates the data is write only (passed from the OCI to the CNC).
R/W indicates the data is both read and write. Errors are generated if
you attempt to write data to a read only OCI data item.
Write privileges for commands and API data items are reserved for
the controlling OCI station. You must first successfully issue the
REQUEST_CONTROL command before write requests will be
accepted by the OCI station. Refer to the command chapter for
details on issuing the REQUEST_CONTROL command.