Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual
Page 224
OCI Error Handling
C–9
Publication 8520-6.6. - August 1999
5012
"MOTION NOT ALLOWED"
5013
"NEGATIVE DWELL VALUE"
5014
"ROTARY WORD OUT OF RANGE"
5015
"NOT ALLOWED - THREADING ACTIVE"
5016
"NOT ALLOWED - G41/G42 ACTIVE"
5017
"CHANGE NOT MADE IN BUFFERED BLOCKS"
5018
"CIRCULAR PROGRAMMING ERROR"
5019
"ILLEGAL (/) VALUE"
5020
"DECIMAL POINT NOT ALLOWED" 20
5021
"ILLEGAL CHARACTER"
5022
"ILLEGAL (G) CODE"
5023
"+/- SIGN ERROR"
5024
"BLOCK LENGTH ERROR"
5025
"NEGATIVE VALUE NOT ALLOWED"
5026
"NUMERIC VALUE MISSING"
5027
"PARENTHESIS INPUT ERROR"
5028
"ENTRY OUT OF RANGE"
5029
"RADIUS TOO SMALL"
5030
"MOTION IN DWELL BLOCK" 30
5031
"NO FEEDRATE PROGRAMMED"
5032
"PLANE SELECT ERROR"
5033
"ILLEGAL MACRO CMD VIA MDI"
5034
"TOO MANY G67'S"
5035
"MISSING PROGRAM NUMBER (P)"
5036
"CALLED 7300 PATTERN NAME IS BAD" not used
5037
"TOO MANY MACRO CALLS"
5038
"TOO MANY SUBPROGRAM CALLS"
5039
"CANNOT OPEN SUBPROGRAM"
5040
"(GOTO) SEQ. NUMBER NOT FOUND" 40
5041
"CANNOT (GOTO) TO INSIDE A (DO)"
5042
"MISSING A (DO) COMMAND"
5043
"INVALID (DO) COMMAND NUMBER"
5044
"TOO MANY NESTED (DO) COMMANDS"
5045
"INVALID (END) COMMAND NUMBER"
5046
"(+) OVERTRAVEL PROGRAM ERROR"
5047
"(-) OVERTRAVEL PROGRAM ERROR"
- 20P PowerFlex DC Drive - Frame D Bimetal Thermostat (10 pages)
- 1336S_F_T_E_R F Frame Snubber Resistor Repl. (6 pages)
- 22-COMM PowerFlex 4-Class DSI (Drive Serial Interface) Network Communication Adapter (4 pages)
- 8-545 Plug In Solid State Relay (2 pages)
- 20-HIM-B1 PowerFlex 7-Class HIM Bezel (DPI) (4 pages)
- 100 Contactors with DC Coil (1 page)
- 100 Contactors with DC Coil (2 pages)
- 20P PowerFlex DC Drive - Frame D Switching Power Supply Circuit Board (6 pages)
- 140G-MTFx_MTHx_MTIx_MTKx Trip Unit Installation-140G-M (6 pages)
- 45BRD Analog Laser Sensor (4 pages)
- 20D Multi-Device Interface Option Board for PowerFlex 700S Drives (20 pages)
- 56RF RFID 18 mm Cylindrical Transceiver (2 pages)
- 42KC Miniature Rectangular: 5V DC Version (2 pages)
- 20P PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board (16 pages)
- 21P-MISC-A-TP-2 Transition Tube Kit #C19-6/7 For PowerFlex 755 w/OEM Liquid Cooling Fr 6/7 Drive (2 pages)
- 42BT Background Suppression Sensor (3 pages)
- 42CB High Speed 18mm Cylindrical (4 pages)
- 140EX-JE2_JE3 Molded Case Circuit Breaker (4 pages)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (1 page)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (3 pages)
- 20-HIM-A6 PowerFlex (Human Interface Module) (74 pages)
- 42CF General Purpose 12mm Cylindrical (4 pages)
- 20D PowerFlex 700S Phase II Drive Frames 1...6 (80 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (6 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (4 pages)
- 20B PowerFlex 700 Custom Firmware - Pump Off (12 pages)
- 20-WIM-N4S DPI Wireless Interface Module (92 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (7 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (2 pages)
- 60-2619, 42JS Swivel/Tilt Mounting Bracket (1 page)
- 22A PowerFlex 4/40/400 Flange Mount (4 pages)
- 45MLA Controller Installation Instructions (16 pages)
- 20P PowerFlex DC Drive - Cooling Fan for Frame A Drives Above 73A at 230V 460V AC (6 pages)
- 42JS Series 7000 to 42JS VisiSight Replacement Kit (2 pages)
- 22A PowerFlex 4-Class HIM Bezel (DSI) (4 pages)
- 42CS Stainless Steel Photoelectric Sensors (4 pages)
- 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger (40 pages)
- 20P PowerFlex DC Drive - Frame B SCR Modules (20 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (161 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (22 pages)
- 22F PowerFlex 4M Input RFI Filters (2 pages)
- 45LFM Capacitive Label Sensor (4 pages)
- 140G-Rx Installation Instruction-140G-R (2 pages)
- 140G-Rx Installation Instruction-140G-R (29 pages)
- 22C PowerFlex 400 AC Drive Quick Start - FRN 1-4.xx (28 pages)