beautypg.com

B - oci commands, Oci commands, Appendix – Rockwell Automation 8520-9API 9/Series OCI API Developer's Guide User Manual

Page 209: Amp commands, Axis calibration

background image

Appendix

B

Publication 8520-6.6. - August 1999

OCI Commands

Inst

ID

Item (Name)

Command Description

Control Type

OCI / 9/PC

# Params

Dual

Proc.

Parameter 1

P1 type

Parameter 2

P2 type

Parameter 3

P3 type

AMP Commands

42

BACKUP_AMP

Send AMP to backup storage

All Controls

Both

No

44

MODIFYING_AMP

Modifying AMP for patch AMP utility

All Controls

Both

No

43

RESTORE_AMP

Sends AMP from backup storage

All Controls

Both

No

49

TRANSFER_AMP_FROM_PORTA

AMP from port A

All Controls

OCI

No

53

TRANSFER_AMP_FROM_PORTB

AMP from port B

All Controls

OCI

No

48

TRANSFER_AMP_TO_PORTA

AMP to port A

All Controls

OCI

No

52

TRANSFER_AMP_TO_PORTB

AMP to port B

All Controls

OCI

No

56

TRANSFER_HOMECAL_TO_PORTA

Home calibration to port A

All Controls

OCI

Yes

62

TRANSFER_HOMECAL_TO_PORTB

Home calibration to port B

All Controls

OCI

Yes

58

TRANSFER_REVERSAL_ERROR_TO_

PORTA

Reversal error to port A

All Controls

OCI

Yes

64

TRANSFER_REVERSAL_ERROR_TO_

PORTB

Reversal error to port B

All Controls

OCI

Yes

45

UPDATE_AMP

Updates AMP on control after patch AMP modiĆ

fication

All Controls

Both

No

Axis Calibration

46

BACKUP_AXISCALOCI

Sends axis calibration to backup storage

All Controls

Both

No

41

DELETE_AXISCAL_POINT

Deletes axis calibration point

All Controls

Both

2

Yes

Logical Axis Number

DINT

Axis Cal Point No

DINT

148

DELETE_ALL_AXISCAL_POINTS

Deletes ALL axis calibration point all axes

All Controls

Both

Yes

68

ENTER_AXISCAL_MODIFY_MODE

Gets axis calibration data

All Controls

Both

No

69

EXIT_AXISCAL_MODIFY_MODE

Sends axis calibration data

All Controls

Both

No

39

INITIALIZE_AXISCAL_TABLE

Initializse axis calibration table

All Controls

Both

3

Yes

Logical Axis Number

DINT

Cal Type enum

DINT

Cal Start enum

DINT

40

INSERT_AXISCAL_POINT

Insert axis calibration point

All Controls

Both

1

Yes

Logical Axis Number

DINT

155

NEXT_AXISCAL_AXIS

Selects the axis for axiscal operations

All Controls

Both

1

Yes

Logical Axis Number

DINT

65

REPLACE_AXISCAL_VALUE

Replaces axis calibration values in table

All Controls

Both

3

Yes

Logical Axis Number

DINT

Axis Cal Point No

DINT

Axiscal Meas/Deviation

Value

LREAL

47

RESTORE_AXISCAL

Sends axis calibration from backup storage

All Controls

Both

No

154

SET_AXISCAL_PROCESS_NUMBER

Sets the process number for axiscal

All Controls

Both

1

No

Process Number

DINT

5

STOP_AXISCAL

Disables axis calibration on the specified axis

All Controls

Both

1

No

Logical Axis Number

DINT

61

TRANSFER_AXISCAL_FROM_PORTA

Axis calibration from port A

All Controls

OCI

No

67

TRANSFER_AXISCAL_FROM_PORTB

Axis calibration from port B

All Controls

OCI

No