Bit definitions for, Data types for instance – Rockwell Automation 2098-IPD-020-DN Ultra5000 Series Intelligent Positioning Drives with DeviceNet Reference Manual User Manual
Page 75
Publication 2098-RM002A-EN-P – October 2001
Programming Reference
4-51
Parameter Object
Bit Definitions for Instance Attribute 4
Bit Definition
Value
0
Supports settable
path
0 = Link path can not be set.
1 = Link path can be set.
1
Supports
enumerated strings
0 = Enumerated strings are not supported.
1 = Enumerated strings are supported and may be read with
the Get_Enum_String service.
2
Supports scaling
0 = Scaling not supported.
1 = Scaling is supported. The scaling attributes are
implemented and the value presented is in engineering
units.
3
Supports scaling
links
0 = Scaling links not supported.
1 = The values for the scaling attributes may be retrieved
from other parameter object instances.
4
Read only parameter 0 = Parameter value attribute can be written (set) and read
(get). Access rule is set.
1 = Parameter value attribute can only be read. Access rule is
get.
5
Monitor parameter
0 = Parameter value attribute is not updated in real time by
the device.
1 = Parameter value attribute is updated in real time by the
device.
6
Supports extended
precision scaling
0 = Extended precision scaling is not supported.
1 = Extended precision scaling should be implemented and
the value is presented in engineering units.
Parameter Object
Data Types for Instance Attribute 5
Data Type Name
Data Type Code
(in Hex)
Data Type
Description
SINT
C2
Signed 8-bit integer value
INT
C3
Signed 16-bit integer value
DINT
C4
Signed 32-bit integer value
USINT
C6
Unsigned 8-bit integer value
UINT
C7
Unsigned 16-bit integer value
UDINT
C8
Unsigned 32-bit integer value
REAL
CA
32-bit floating point value
BYTE
D1
bit string, 8-bit
WORD
D2
bit string, 16-bit
DWORD
D3
bit string, 32-bit
SHORT_STRING
DA
Character string
(1 byte per character, 1 byte length indicator)