Rockwell Automation 2098-IPD-020-DN Ultra5000 Series Intelligent Positioning Drives with DeviceNet Reference Manual User Manual
Page 63

Publication 2098-RM002A-EN-P – October 2001
Programming Reference
4-39
162
Get
Input 13 State
USINT
1
The current state, or condition, of the digital
input.
0 = Off
1 = On
163
Get
Input 14 State
USINT
1
The current state, or condition, of the digital
input.
0 = Off
1 = On
164
Get
Input 15 State
USINT
1
The current state, or condition, of the digital
input.
0 = Off
1 = On
165
Get
Input 16 State
USINT
1
The current state, or condition, of the digital
input.
0 = Off
1 = On
166
Set
Output 1 State
USINT
1
The current state, or condition, of the digital
output. Not saved in non-volatile memory.
0 = Off (default)
1 = On
167
Set
Output 2 State
USINT
1
The current state, or condition, of the digital
output. Not saved in non-volatile memory.
0 = Off (default)
1 = On
168
Set
Output 3 State
USINT
1
The current state, or condition, of the digital
output. Not saved in non-volatile memory.
0 = Off (default)
1 = On
169
Set
Output 4 State
USINT
1
The current state, or condition, of the digital
output. Not saved in non-volatile memory.
0 = Off (default)
1 = On
170
Set
Output 5 State
USINT
1
The current state, or condition, of the digital
output. Not saved in non-volatile memory.
0 = Off (default)
1 = On
171
Set
Output 6 State
USINT
1
The current state, or condition, of the digital
output. Not saved in non-volatile memory.
0 = Off (default)
1 = On
172
Set
Output 7 State
USINT
1
The current state, or condition, of the digital
output. Not saved in non-volatile memory.
0 = Off (default)
1 = On
Parameter Object,
Instances ID 1- 340
Parameter
Instance
Access
Rule
Parameter
Name
Data
Type
Data
Size
(Bytes)
Units /
Scale
Description