Array index 5 – i/o transmit select, Array index 5 – i/o transmit select -4 – Rockwell Automation 2098-IPD-020-DN Ultra5000 Series Intelligent Positioning Drives with DeviceNet Reference Manual User Manual
Page 18

Publication 2098-RM002A-EN-P – October 2001
2-4
DeviceNet Driver Installation
Array Index 5 – I/O Transmit Select
Selects the input (produced) assembly that is transmitted by the drive
over a Polled I/O Messaging Connection. If the value is modified, you
have to either close any existing I/O Messaging connection(s), power
cycle the drive, reset the drive, or remove and reapply DeviceNet
power for the drive to use the modified value.
Refer to Assembly Object, Instance ID = 1 - 16 on page 4-12 for
information on the data format.
Value Description
0
No data produced.
1
2
DNetIntArray[0], DNetIntArray[1]
3
4
DNetFltArray[0], DNetFltArray[1]
5
DNetIntArray[0], DNetFltArray[0]
6
DNetIntArray[0], DNetIntArray[1], DNetFltArray[0]
7
DNetIntArray[0], DNetFltArray[0], DNetFltArray[1]
8