Publication 2098-RM002A-EN-P – October 2001
4-48
Programming Reference
265
Get
Motor Encoder
Type
USINT
1
Type of motor encoder.
0 = None
1 = Incremental
2 = Sine/Cosine
3 = Intelligent
266
Get
Motor
Commutation
Type
USINT
1
The type of motor commutation.
0 = Brush
1 = Trapezoidal
2 = Sinusoidal
267
Get
Motor Startup
Type
USINT
1
The type of motor startup for sinusoidal
commutation.
0 = Self-Sensing
1 = Hall Inputs
268
Get
Motor Hall Offset REAL
4
degs
Hall Input offset in units of electrical degrees.
269
Get
Motor Rotary
Line Count
DINT
4
lines/ rev
The number of encoder lines per revolution on a
rotary motor encoder.
270
Get
Motor Linear Line
Count
DINT
4
lines/m
The number of encoder lines per meter of travel
on a linear motor encoder.
271
Get
Motor
Thermostat
USINT
1
Indicates whether the motor has a built-in
thermostat.
0 = Not Present
1 = Present
272
Get
Motor Soft
Protection
USINT
1
Determines whether the motor thermal protection
software is activated.
0 = Disabled
1 = Enabled
273
Get
Motor Rth(w-e)
REAL
4
C/W
Thermal resistance from the winding to the
encoder.
274
Get
Motor Cth(w-e)
REAL
4
W-s/C
Thermal capacitance from the winding to the
encoder.
275
Get
Motor Rth(w-a)
REAL
4
C/W
Thermal resistance from the winding to ambient.
276
Get
Motor Cth(w-a)
REAL
4
W-s/C
Thermal capacitance from the winding to
ambient.
277 -
308
Set
Integer Data
0 - 31
DINT
4
Range: -2147483648 to 2147483647
Default: 0
Automatically saved in non-volatile storage.
309 -
340
Set
Float Data 0 - 31 REAL
4
Range: -3.4e10 to 3.4e10
Default: 0
Automatically saved in non-volatile storage.
Parameter Object,
Instances ID 1- 340
Parameter
Instance
Access
Rule
Parameter
Name
Data
Type
Data
Size
(Bytes)
Units /
Scale
Description