Connection object (class id 05h), Connection object (class id 05 – Rockwell Automation 2098-IPD-020-DN Ultra5000 Series Intelligent Positioning Drives with DeviceNet Reference Manual User Manual
Page 40

Publication 2098-RM002A-EN-P – October 2001
4-16
Programming Reference
Connection Object
(Class ID 05
H
)
The Connection Object manages the internal resources associated
with both I/O and Explicit Messaging Connections. The specific
instance generated by the Connection Class is referred to as a
Connection Instance or a Connection Object. A Connection Object
within a particular module actually represents one of the end-points of
a connection.
DeviceNet Connection Object,
Instance ID = 1 - 10
Instance
ID
Instances
1
Group 2 Explicit Message Connection
2
Poll I/O Connection
6-10
Group 3 Explicit Message Connections
DeviceNet Connection Object,
Attributes of Instances ID = 1 - 10 /
Attr ID
Access
Rule
Attribute
Name
Data Type Description
1
Get
State
USINT
State of the Connection
2
Instance Type
I/O or Message Connection
3
Transport_class_trigger
BYTE
Defines the behavior of the Connection
4
Produced_connection_id
UINT
CAN identifier to transmit on
5
Consumed_connection_id
CAN identifier to receive on
6
Initial_comm_characteristics
BYTE
Defines the Message Group(s) associated with
this Connection
7
Produced_connection_size
UINT
Maximum number of bytes transmitted across
this Connection
8
Consumed_connection_size
Maximum number of bytes received across this
Connection
9
Set
Expected_packet_rate
Defines timing associated with this Connection
12
Watchdog_timeout_action
USINT
Defines how to handle Inactivity/Watchdog
timeouts
13
Get
Produced_connection_path_
length
UINT
Number of bytes in the
produced_connection_path attribute
14
Produced_connection_path
EPATH
Specifies the Application Object whose data is
to be produced by this Connection object
15
Consumed_connection_path_length
UINT
Number of bytes in the
Consumed_connection_path attribute
16
Consumed_connection_path
EPATH
Specifies the Application Object(s) that are to
receive the data consumed by this Connection
17
Set
Production_inhibit_time
UINT
Defines minimum time between new data
production for COS connections.