Communicate over Networks

Chapter 4

Additional Resources

Table 11 - DF1 Modes for Logix5000 Controllers

Mode

Functions

DF1
Point-to-Point

Communication between a controller and one other DF1-protocol-compatible device.
This is the Default System mode. These are the default parameters:
Communication Rate: 19,200 bps
Data Bits: 8
Parity: None
Stop Bits: 1
Control Line: No Handshake
RTS send Delay: 0
RTS Off Delay: 0

This mode is typically used to program a controller through its serial port.

DF1 Master

Control of polling and message transmission between the master and slave nodes.
The master/slave network includes one controller configured as the master node and up to 254

slave nodes. Link slave nodes using modems or line drivers.

A master/slave network can have node numbers from 0...254. Each node must have a unique

node address. Also, for your link to be a network, it must consist of one master and one slave
station.

DF1 Slave

A controller to operate as a slave station in a master/slave serial communication network.
When there are multiple slave stations on the network, link slave stations by using modems or

line drivers to the master. When you have a single slave station on the network, you do not
need a modem to connect the slave station to the master. You can configure the control
parameters for no handshaking. You can connect 2...255 nodes to a single link. In DF1 Slave
mode, a controller uses DF1 half-duplex protocol.

One node is designated as the master and controls who has access to the link. All of the other

nodes are slave stations and must wait for permission from the master before transmitting.

DF1 Radio
Modem

Compatible with SLC 500 and MicroLogix 1500 controllers.
This mode supports Master and Slave, and Store and Forward modes.

User

Communication with ASCII devices.
This requires your program to use ASCII instructions to read and write data from and to an ASCII

device.

DH-485

Communication with other DH-485 devices.
This multi-master, token-passing network permits programming and peer-to-peer messaging.

Resource

Description

EtherNet/IP Modules in Logix5000 Control Systems User
Manual, publication

ENET-UM001

Contains detailed information on configuring and using
EtherNet/IP communication modules in a Logix5000
control system

ControlNet Modules in Logix5000 Control Systems User
Manual, publication

CNET-UM001

Contains detailed information on configuring and using
ControlNet communication modules in a Logix5000
control system

DeviceNet Modules in Logix5000 Control Systems User
Manual, publication

DNET-UM004

Contains detailed information on configuring and using
the 1756-DNB in a Logix5000 control system