06
.
108
Han
Modular
Han
®
Multi module - DIN 41 626
Features
• Suitable for FOC and coaxial contacts acc. to
DIN 41 626
• Using of guiding pins (male and female) is
imperative (see chapter 95).
Contact arrangement
according to following matrix
Contacts
Male insert (M)
Female insert (F)
"https://b2b.harting.com/ebusiness/en/
Coaxial contacts
09 14 000 62xx
09 14 000 61xx
F.O. contacts
20 10 xxx 421x
20 10 xxx 422x
Coaxial cables (group 2)
Wires
Shell
∅
Internal
wire
∅
Attenuation db/100 m at
mm
mm
100 MHz 200 MHz 800 MHz
50 Ω
RG 174 / U
RG 188 A / U
RG 316 / U
2.5
2.6
2.5
0.48
0.54
0.54
29
40
40
84
75 Ω
RG 179 B / U
RG 187 A / U
2.55
2.7
0.3
0.3
41
41
Technical characteristics
Specifications
DIN EN 60 664-1
DIN EN 61 984
Inserts
Number of contacts
12
Insulation resistance
≥ 10
10
Ω
Material
polycarbonate
Limiting temperatures
-40 °C ... +125 °C
Flammability acc. to UL 94
V 0
Mechanical working life
- mating cycles
≥ 500
Contacts
Coaxial contacts
Material
copper alloy
Surface
- hard-gold plated
demand level 2
Impedance
50 Ω / 75 Ω
Contact resistance
- Internal wire
≤ 10 mΩ
- Outer conductor
≤ 3 mΩ
Rated current
1.5 A
Rated voltage
50 V
F.O. contacts
Fibre type
glas fibre (GI)
Attenuation
< 1.5 dB
F.O. contacts
Fibre type
polymer Optical Fibre (POF)
Attenuation
< 2.5 dB
Assembly instructions
Stripping de-
scription
Assembly details
for coaxial contacts
Crimp barrel
solder
Solder temperature
approx. 300 °C
Solder duration
approx. 2 s
Due to the closed entry design of female insert the upper
part has to be removed by screw driver before extracting the
contacts.