beautypg.com

Multi module, Technical characteristics, Assembly instructions – Northern Connectors Harting Han-Modular Connectors User Manual

Page 108

background image

06

.

108

Han

Modular

Han

®

Multi module - DIN 41 626

Features

• Suitable for FOC and coaxial contacts acc. to

DIN 41 626

• Using of guiding pins (male and female) is

imperative (see chapter 95).

Contact arrangement

according to following matrix

Contacts

Male insert (M)

"https://b2b.harting.com/ebusiness/en/

09 14 004 4501

"

Female insert (F)

"https://b2b.harting.com/ebusiness/en/

09 14 004 4512

"

Coaxial contacts

09 14 000 62xx

09 14 000 61xx

F.O. contacts

20 10 xxx 421x

20 10 xxx 422x

Coaxial cables (group 2)

Wires

Shell

Internal

wire

Attenuation db/100 m at

mm

mm

100 MHz 200 MHz 800 MHz

50 Ω

RG 174 / U

RG 188 A / U

RG 316 / U

2.5

2.6

2.5

0.48

0.54

0.54

29

40

40

84

75 Ω

RG 179 B / U

RG 187 A / U

2.55

2.7

0.3

0.3

41

41

Technical characteristics

Specifications

DIN EN 60 664-1

DIN EN 61 984

Inserts

Number of contacts

12

Insulation resistance

≥ 10

10

Ω

Material

polycarbonate

Limiting temperatures

-40 °C ... +125 °C

Flammability acc. to UL 94

V 0

Mechanical working life

- mating cycles

≥ 500

Contacts

Coaxial contacts

Material

copper alloy

Surface

- hard-gold plated

demand level 2

Impedance

50 Ω / 75 Ω

Contact resistance

- Internal wire

≤ 10 mΩ

- Outer conductor

≤ 3 mΩ

Rated current

1.5 A

Rated voltage

50 V

F.O. contacts

Fibre type

glas fibre (GI)

Attenuation

< 1.5 dB

F.O. contacts

Fibre type

polymer Optical Fibre (POF)

Attenuation

< 2.5 dB

Assembly instructions

Stripping de-

scription

Assembly details

for coaxial contacts

Crimp barrel

solder

Solder temperature

approx. 300 °C

Solder duration

approx. 2 s

Due to the closed entry design of female insert the upper

part has to be removed by screw driver before extracting the

contacts.