Lenze 8615E User Manual
Page 57
55
The arrow position marks whether you are in the code or in the
parameter level.
→
C
0
5
0
0
.
0
H
z
O
u
t
p
u
t
f
r
e
q
u
e
n
c
y
Press, until C011 is displayed
→
C
0
1
1
5
0
.
0
H
z
m
a
x
.
f
r
e
q
u
e
n
c
y
Press PRG to change to the parameter level
C
0
1
1
→
5
0
.
0
H
z
m
a
x
.
f
r
e
q
u
e
n
c
y
Press, until 60 Hz is displayed
C
0
1
1
→
6
0
.
0
H
z
m
a
x
.
f
r
e
q
u
e
n
c
y
The maximum field frequency of 60Hz is now set and is accepted
immediately.
Acceptance with SH + PRG
The inverter accepts a new parameter when SH+PRG are
pressed. This is possible even when the drive is running.
First press SH and then in addition PRG. The display shows --ok--
for 0.5 seconds. The inverter now works with the new parameter.
The key combination SH and PRG can be compared to the "return"
key on your computer keyboard.
If you have to set a parameter in this way, the programming tables
show the symbol SH + PRG.
Acceptance with SH + PRG with controller inhibit
The inverter accepts the new parameter when the controller has
been inhibited before pressing SH + PRG.
Inhibit the controller, e.g. by pressing STP.
First press SH and than in addition PRG. The display shows --ok--
for 0.5 seconds. The inverter works with the new parameter when
controller inhibit is cancelled.
If you have to set a parameter in this way, the programming tables
show the symbol [SH + PRG].