3application-specific controller selection – Lenze 8615E User Manual
Page 18
16
3
Application-specific controller selection
3.1
Applications with extreme overload,
peak torque up to 230% of the rated motor torque
−
For applications where very extreme starting and
overload torques are necessary (e.g. presses, drilling
machines).
−
The inverter provides 200% of the rated torque for a
maximum of 30s.
In the event of cyclic overload, the ratio of overload
time and cycle time must not exceed 0.2.
−
For these applications, the monitoring of the output
current is set to operation with rated power
(factory setting) using the codes C119 and C120
(see page 97)
-
Please note that a maximum ambient temperature of
50°C is permissible.
1
1.5
1.2
1.8
2.3
n
n
N
V/f-control
M
M
N
I -control
0
Type
Order no.
Rated
motor
power
kW
Rated
output
current
A
max.
output
current
A for 30s
Output power
kVA
400V 50Hz 480V 60Hz
Mains
current
A
Power
loss
W
8601
33.8601_E
1.1
3.0
6.0
2.07
2.5
3.0
130
8602
33.8602_E
1.5
3.9
7.8
2.7
3.24
3.9
140
8603
33.8603_E
2.2
5.5
11.0
3.81
4.57
5.5
160
8604
33.8604_E
3.0
7.5
15.0
5.2
6.24
7.0
180
8605
33.8605_E
4.0
9.4
19.0
6.51
7.82
8.8
200
8606
33.8606_E
5.5
13.0
26.0
9.01
10.8
12.0
240
8607
33.8607_E
7.5
16.5
33.0
11.4
13.7
15.0
275
8608
33.8608_E
11.0
23.5
47.0
16.3
19.5
20.5
350
8609
33.8609_E
15.0
32.0
64.0
22.2
26.6
28.5
420
8610
33.8610_E
18.5
39.5
79.0
27.4
32.8
34.5
600
8611
33.8611_E
22.0
47.0
94.0
32.6
39.1
41.0
740
8612
33.8612_E
30.0
60.0
120.0
41.6
49.9
53.0
900
8613
33.8613_E
37.0
75.0
150.0
52.0
62.3
66.0
1050
8614
33.8614_E
45.0
89.0
178.0
61.7
74.0
78.0
1050
8615
33.8615_E
55.0
110.0
220.0
76.2
91.4
96.0
1270