2technical data, 1 general data – Lenze 8615E User Manual
Page 10
8
2
Technical data
2.1
General data
Mains voltage:
3 x 480 V AC, 45 to 65 Hz
Permissible voltage range: 330 ... 528 V
(alternatively 470 to 740 V DC supply)
Output voltage:
3 x 0 to V
mains
(V ~ fd with 400 V at 50 Hz, adjustable, mains-independent)
When using a mains choke, the maximum possible output voltage is
reduced to approx. 96 % of the mains voltage.
Output frequency:
0 ... 50 Hz, adjustable up to 480 Hz
Chopper frequency:
4 kHz factory setting, adjustable from 2 ... 16 kHz
Threshold of the integrated brake
chopper:
765 V DC in the DC bus
Enclosure:
Steel-sheet housing, IP20 to DIN 40050
Ambient temperature:
0 to 50 °C during operation
(for rating see page 11)
-25 to 55 °C during storage
-25 to 70 °C during transport
Noise immunity:
Severity class 4 to IEC 801-4
Permissible pollution:
Pollution level
˝ 2 to VDE 0110, part 2. The inverter should not be exposed to
corrosive or explosive gases.
Permissible humidity:
relative humidity 80 %, no condensation
Influence of installation altitude on
the rated current:
1000 m: 100 % rated current
2000 m: 95 % rated current
3000 m: 90 % rated current
4000 m: 85 % rated current