3 display of actual values, 4 switch-on display, 5 identification – Lenze 8615E User Manual
Page 102

100
8.3
Display of actual values
Under codes C050 to C054 you can read different actual values.
Code
Act. value
Display
C050
Output frequency
absolute in Hz
C051
Feedback of PI controller
with C172 = -0-: related to f
dmax
with C172 = -1-: absolute in Hz
C052
Motor voltage
absolute in V
eff
C053
DC bus voltage
absolute in V
C054
Motor current
absolute in A
eff
8.4
Switch-on display
If you connect the inverter to the mains, the output frequency is
shown as the first display (C050). If you want to set another
information as switch-on display, enter the corresponding code
number under C004.
Code
Parameter
Meaning
Acceptance
C004
xxx
Code number for display after mains
connection
SH + PRG
8.5
Identification
On the display of the keypad you can see which software version is
loaded in the inverter. For this, select code C099.
If you work with LECOM, you can see the inverter type under C093.