9code table – Lenze 8615E User Manual
Page 103
101
9
Code table
The following table shows which settings you can enter under which
codes. For detailed explanations of the codes and their possible
functions refer to the corresponding chapters.
How to read the code table:
Column
Abbreviation
Meaning
Code
C000
C005*
Code of the standard code set
Code of the extended code set
Parameter
-0-
Factory settings are printed in bold.
Acceptance
ON-LINE
SH + PRG
[SH + PRG]
Controller immediately accepts the new parameter
Controller accepts the new parameters after pressing SH + PRG
Controller accepts the new parameters only if the controller is inhibited when
pressing SH + PRG.
Code
Name
Parameter
(Factory settings are printed in bold)
Acceptance see
page
Your
settings
C000
Code set
-0-
Standard code set read only
-1-
Standard code set
-2-
Extended code set
-9-
Service code set
SH + PRG
54,
99
C001
Operating
mode
Control
Programming
-0-
Terminals
Keypad
-1-
Keypad
Keypad
-2-
Terminals
LECOM 1(X6)
-3-
LECOM 1 (X6)
LECOM 1 (X6)
-4-
Terminals
LECOM 2
-5-
LECOM 2
LECOM 2
-6-
LECOM 2
Keypad
-7-
LECOM 2
LECOM 1
[SH + PRG] 57
C002
Load
parameter set
-0-
Factory setting
-1-
Parameter set 1
-2-
Parameter set 2
-3-
Parameter set 3
-4-
Parameter set 4
[SH + PRG] 56,
85
C003
Store
parameter set
-1-
Parameter set 1
-2-
Parameter set 2
-3-
Parameter set 3
-4-
Parameter set 4
SH + PRG
56,
85
C004
Switch-on
display
xxx
Code number for display after mains
connection
SH + PRG
100
C005
Configuration
-0-
Open-loop control, unipolar,
without set-value 2
With -0- and operation via serial
interface,the set-value can be entered
bipolar under C046.
-1-
Open-loop control, bipolar
-2-
Open-loop control with digital frequency
-11-
Closed-loop control with analog
feedback
-13-
Closed-loop control with
incremental encoder feedback
-14-
Closed-loop control with digital
frequency set-value via X8 and
incremental encoder feedback via X5
-15-
Closed-loop control with digital frequency
set-value via X5 and incremental
encoder feedback via X8
[SH + PRG] 60,
73
C006
Control mode
-0-
V/f characteristic control
-1-
I0 -control
[SH + PRG] 67