Parameter setting, 1keypad, 1 key functions – Lenze 8615E User Manual
Page 55: 2 plain text display

53
Parameter setting
1
Keypad
Plain text display
PRG
SH
STP
RDY
IMP
LENZE 8600
UMRICHTER
max
I
Operating keys
Display of status:
Ready for operation (LED green)
Imax-limit reached (LED red)
Pulse inhibit (LED yellow), released
by:
−
Controller inhibit
−
Fault indication (TRIP)
−
Undervoltage/overvoltage
1.1
Key functions
Key
Function
PRG
Change between code and parameter level
SH +
PRG *
Accept change
Increase displayed number
SH +
Increase displayed number fast (scroll up)
Reduce displayed number
SH +
Reduce displayed number fast (scroll down)
STP
Inhibit controller
SH +
STP *
Enable controller
* First press the SH key and then in addition the PRG or the STP key.
1.2
Plain text display
Position of the arrow
→
marks the activated operating level
(code/parameter level)
↓
Code
↓
Parameter Unit
C
0
5
0
→
0
.
0
H
z
Example
O
u
t
p
u
t
f
r
e
q
u
e
n
c
y
Explaining text for each code and parameter