10.4
Attribute table
If you want to write programs yourself, the following table gives you
information for the serial communication via LECOM1 (LECOM-
A/B) or LECOM2.
Legend
Code
Meaning
Code
Lenze code number
DS
Data structure
E =
Single variable (only one parameter element)
A =
Array variable (several parameter elements can be selected by the code for the
preselection or by LECOM sub code).
I =
Image variable (several parameter elements can only be selected by the code for
the preselection)
P/S
Parameter setting/Control (Combination according to C001)
P =
Parameter setting
S =
Control
DT
Data type
B8 =
1 Byte bit coded
B16 =
2 Byte bit coded
VS =
ASCII String
FIX32 = 32-bit value with sign; decimal with four decimal places
Examples:
1.2 = 12000
FIX32-dez
00002EEO
FIX32-hex
-10.45 = -104500
FIX32-dez
FFFE67CC
FIX32-hex
N16 = 16-bit value with sign; 0 = 0; 100% = 2
14
100% = 16384
N16-dez
4000
N16-hex
-50% = -8192
N16-dez
E000
N16-hex
DL
Data length in byte
LCM-R/W
Access authorization for LECOM
Ra
= Reading is always permitted
W
= Writing permitted under certain conditions (e.g. operating mode, controller inhibit)
Wa
= Writing is always permitted
LCM1-Form.
LECOM A/B format (see technical description LECOM A/B)
AIF-PZD
High resolution data in automation interface.
Mapping on LECOM2 high resolution channel is possible.
PZD =
High resolution data
LCM2-Index
Number (Index) under which the parameter is addressed when using LECOM 2.