3 description of the analog inputs and outputs, 4 description of other inputs and outputs – Lenze 8615E User Manual
Page 31

29
5.2.3 Description of the analog inputs and outputs
Analog inputs
Terminal
Switch setting
Use
(factory setting)
Level/Resolution
Parameter
setting see
page
1, 2
Set-value 2
-10V...+10V
12bit + sign
66
3, 4
ON
OFF
S1
1
2
3
Actual value
-10V...+10V
12bit + sign
73 and 66
Actual value
-30V...+30V
12bit + sign
73 and 66
Actual value
-60V...+60V
12bit + sign
73 and 66
Actual value
-90V...+90V
12bit + sign
73 and 66
Actual value
-120V...+120V
12bit + sign
73 and 66
7
internal ground (GND)
−
8
Set-value 1, Master
voltage
-10V...+10V
12bit + sign
64
Set-value 1,
master current
-20mA...+20mA or
±
4...20mA
64 and 66
9
Voltage supply for
potentiometer
+10V/7mA
−
10
Voltage supply for
potentiometer
-10V/7mA
−
Analog outputs (monitor outputs)
Terminal
Switch setting
Use
(factory setting)
Level
Parameter
setting see
page
60
internal ground (GND)
−
62
Monitor 1 (Output
frequency)
-10V...+10V
89
Monitor 1 (output
frequency)
-20mA...+20mA
89
63
Monitor 2 (output current)
-10V...+10V
89
Monitor 2
(output current)
-20mA...+20mA
89
5.2.4 Description of other inputs and outputs
Terminal
Use
(factory setting)
Parameter
setting see
page
11, 12
Input for temperature monitoring of the connected motor
(PTC thermistor/thermal contact)
If a thermistor/thermal contact is not used:
-
Link terminals 11 and 12 or deactivate function
97
K11, K14
Relay output, Contact capacity: 50V/0.5A
(Trip fault indication)
86
VE9
Supply input for connected incremental encoder (X5/X8)
−
GND
internal ground (GND)
−
FE
Functional earth
−