beautypg.com

Lenze 8615E User Manual

Page 16

background image

14

Considered basic standards for the test of noise immunity:

Basic standard

Test

Limit value

IEC 801-2 /91

Electrostatic discharge
on housing and heat sink

Severity 3
6 kV for contact
8 kV clearance

IEC 1000-4-3

Electromagnetic fields
Frequency range: 26...1000 MHz

Severity 3
10 V/m

ENV 50140 /93

High frequency field
Frequency range: 80...1000 MHz,
80 % amplitude modulated

Severity 3
10 V/m

Fixed frequency 900 MHz with 200 Hz
100% modulated

10 V/m

IEC 801-4 /88

Fast transients,
burst on power terminals

Severity 3
2 kV / 5 kHz

Burst on bus and control cables

Severity 4
2 kV / 5 kHz

IEC 801-5

Surge strength test on
mains cables
This basic standard is applied in addition
to the requirements of the prEN 50082-2.

Installation class 3

Hameln, November 27, 1995

...........................................

...........................................

(i.V. Langner)

(i.V. Tinebor)

Product manager

Enginee in charge of

CE