Code
Name
Parameter
(Factory settings are printed in bold)
Acceptance see
page
Your
settings
C008
Output signal
digital
frequency
-0-
Output of input signals at X5
-2-
Main set-value (C046/JOG)
-3-
Ramp generator output
(main set-value)
-5-
Total set-value
SH + PRG
90
C009*
Controller
address (only
for LECOM)
1
1...99
SH + PRG
110
C010
Minimum field
frequency
0.0Hz
0.0...480Hz
(in steps of 0.1Hz from 0.0 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE
71
C011
Maximum field
frequency
50Hz
7.5...480Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE
71
C012
Acceleration
time
main set-value
5.0s
0.0...990s
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 990s)
ON-LINE
72
C013
Deceleration
time
main set-value
5.0s
0.0...990s
(in steps of 10ms from 0.0 to 1s
in steps of 100ms from 1 to 10s
in steps of 1s from 10 to 100s
in steps of 10s from 100 to 990s)
ON-LINE
72
C014
V/f
characteristic
-0-
linear characteristic V
∼
f
d
-1-
square characteristic V
∼
f
d
2
SH + PRG
68
C015
V/f rated
frequency
50Hz
7.5...960Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 960Hz)
ON-LINE
68,
70
C016
Voltage boost
0.0%
0... 40%
(in steps of 0.1%)
ON-LINE
69
C017
Threshold for
Q
min
function
2.0Hz
0.0...480Hz
(in steps of 0.1Hz from 7.5 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE
87
C018
Chopping
frequency
-0-
1kHz (field frequency max. 120 Hz)
-1-
2kHz (field frequency max. 240 Hz)
-2-
4kHz variable
-3-
6kHz variable
-4-
8kHz variable
-5-
12kHz variable
-6-
16kHz variable
-7-
12kHz fixed (for motor supply filter)
-8-
16kHz fixed (for motor supply filter)
[SH + PRG] 91
C019
Threshold for
automatic DC
injection
braking
0.0Hz
0.0...480Hz
0.0Hz = automatic DC injection braking
switched off
(in steps of 0.1Hz from 0.0 to 100Hz
in steps of 1Hz from 100 to 480Hz)
ON-LINE
92
C020
I
0
set-value
Rated set-value (P
Nmotor
= P
Ncopntroller
)
0.0...0.5
⋅
I
maxcontroller
(in steps of 0.1 A from 0.0 to 100 A
in steps of 1 A as of 100 A)
ON-LINE
70
C021
Slip
compensation
0.0%
0.0...20 %
(in steps of 0.1%)
ON-LINE
92
C022
I
max
limit
I
maxcontroller
0.08...1.0
⋅
I
maxcontroller
(in steps of 0.1A to 100A
in steps of 1A ab 100A)
ON-LINE
87