beautypg.com

4 control terminals, Control terminals, Wiring the device – Lenze E94ASHE Axis Single Drive 32-104A User Manual

Page 68: 4 control terminals system bus can on board, 24 v supply, Analog inputs, analog outputs

background image

Wiring the device

Control terminals

5

l

68

EDK94SH104 DE/EN/FR/ES/IT 5.1

5.4

Control terminals

System bus CAN on board

Terminal X1

Labelling

Description

Pin 2

CAN−LOW

Pin 3

CAN−GND

Pin 7

CAN−HIGH

9400SSP000X1

(Housing)

CAN−Shield

24 V supply

Terminal X2

Labelling

Description

GE

GND external supply

24E

24 V external supply via a safely separated power supply
unit (SELV/PELV) (only required for mains−independent supply of the
control electronics)

9400SSP000X2

SB

State bus in/out (reference GE)

Terminal data

Conductor cross−section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

0.2 ... 2.5

24 ... 12

Spring terminal

With wire end
ferrule

Analog inputs, analog outputs

Terminal X3

Labelling

Description

GA

GND analog signals

AO1

Analog output 1

AO2

Analog output 2

A1+

Analog input 1 +

A1−

Analog input 1 −

A1−

Analog input 1 −

A1R

Terminating resistor for ±20mA

A2+

Analog input 2 +

A2−

Analog input 2 −

SSP94000X3

"

Shield connection: Fix the shield with EMC wire clamp.

Terminal data

Conductor cross−section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb−in]

Flexible

0.2 ... 2.5

24 ... 12

Spring terminal

With wire end
ferrule