4 control terminals, Control terminals, Wiring the device – Lenze E94ASHE Axis Single Drive 32-104A User Manual
Page 68: 4 control terminals system bus can on board, 24 v supply, Analog inputs, analog outputs

Wiring the device
Control terminals
l
68
EDK94SH104 DE/EN/FR/ES/IT 5.1
5.4
Control terminals
System bus CAN on board
Terminal X1
Labelling
Description
Pin 2
CAN−LOW
Pin 3
CAN−GND
Pin 7
CAN−HIGH
9400SSP000X1
(Housing)
CAN−Shield
24 V supply
Terminal X2
Labelling
Description
GE
GND external supply
24E
24 V external supply via a safely separated power supply
unit (SELV/PELV) (only required for mains−independent supply of the
control electronics)
9400SSP000X2
SB
State bus in/out (reference GE)
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule
Analog inputs, analog outputs
Terminal X3
Labelling
Description
GA
GND analog signals
AO1
Analog output 1
AO2
Analog output 2
A1+
Analog input 1 +
A1−
Analog input 1 −
A1−
Analog input 1 −
A1R
Terminating resistor for ±20mA
A2+
Analog input 2 +
A2−
Analog input 2 −
SSP94000X3
"
Shield connection: Fix the shield with EMC wire clamp.
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule