beautypg.com

2 residual hazards, Residual hazards, Safety instructions – Lenze E94ASHE Axis Single Drive 32-104A User Manual

Page 53

background image

Safety instructions

Residual hazards

2

l

53

EDK94SH104 DE/EN/FR/ES/IT 5.1

2.2

Residual hazards

Protection of persons

ƒ

Before working on the controller, check that no voltage is applied to the power
terminals, because
– depending on the controller − the power terminals U, V, W, +UG, −UG, Rb1 and Rb2

carry hazardous voltages for up to 3 to 20 minutes after mains disconnection.

– the power terminals L1, L2, L3; U, V, W, +UG, −UG, Rb1 and Rb2 carry hazardous

voltages when the motor is stopped.

Device protection

ƒ

Plug on or pull off all pluggable terminals only in deenergised condition!

ƒ

Cyclically switching on and off of the mains voltage can overload and destroy the
input current limitation of the controller:
– In the case of cyclic mains switching for a longer time period, allow at least one

minute between two switch−on actions!

Motor protection

ƒ

Depending on the controller settings, the connected motor can be overheated by:
– For instance, longer DC−braking operations.
– Longer operation of self−ventilated motors at low speed.

Protection of the machine/system

ƒ

Drives can reach dangerous overspeeds (e.g. setting of high output frequencies in
connection with motors and machines unsuitable for such conditions):
– The controllers do not offer any protection against such operating conditions. Use

additional components for this purpose.