beautypg.com

3 technical data, 1 general data and operating conditions, Technical data – Lenze E94ASHE Axis Single Drive 32-104A User Manual

Page 56: General data and operating conditions, 3technical data

background image

Technical data

General data and operating conditions

3

l

56

EDK94SH104 DE/EN/FR/ES/IT 5.1

3

Technical data

3.1

General data and operating conditions

Information on mains

Mains types

With earthed

*

point

Unrestricted use

IT systems

Observe instructions on specific measures!

Noise emission

EN 61800−3

Cable−guided, motor cable length up to 50 m: category C2

Noise immunity

EN 61800−3

Category C3

Conformity and approval

Conformity

CE

2006/95/EC

Low−voltage directive

Approval

UL

UL 508C

Power Conversion Equipment, File No. 132659

Protection of persons and devices

Enclosure

EN 60529

IP 20

Not in the wire range of
the terminals on the
motor side

NEMA 250

Protection against contact to
type 1

Insulation resistance

EN 61800−5−1

Overvoltage category III
Reduction from 2000 m amsl onwards: Overvoltage category
II

Insulation of control
circuits

EN 61800−5−1

Safe mains isolation by double/reinforced insulation.

Short−circuit strength

EN 61800−5−1

Motor connection: with restrictions, fault acknowledgement
required
Control connections: without restrictions

Motor protective
measures against

l

Short circuit

l

Earth fault

l

Overvoltage

l

Motor stalling

l

Motor overtemperature
(PTC or thermal contact, I

2

t monitoring)

Discharge current

EN 61800−5−1

> 3.5 mA AC, > 10 mA DC

Observe regulations and
safety instructions!

Cyclic mains switching

Cyclic mains switching of 5 times in 5 minutes is permissible
without restrictions.