C286/12
C286/13
C286/14
Parameter | Name:
C286/12 | ECAT counter: Acyclic frames
Data type: UNSIGNED_32
Index: 24289.12 =
0x5EE1.0x0C
Number of acyclic frames
Display range
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C286/13 | ECAT counter: Acyclic datagrams
Data type: UNSIGNED_32
Index: 24289.13 =
0x5EE1.0x0D
Number of acyclic datagrams
Display range
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C286/14 | ECAT Clear specific counters
Data type: UNSIGNED_32
Index: 24289.14 =
0x5EE1.0x0E
Reset of frame and datagram counters (C1086/7 ... 13)
Selection list
(Lenze setting printed in bold)
0 No Operation
1 Clear all Counters
2 Clear TX-Frame Counter
4 Clear RX-Frame Counter
8 Clear Lost Frame Counter
16 Clear Cyclical Frame Counter
32 Clear Cyclical Datagram Counter
64 Clear Acyclic Frame Counter
128 Clear Acyclic Datagram Counter
Read access Write access CINH PLC-STOP No transfer