3 l_etc_getmasterdiagnostic (fb), L_etc_getmasterdiagnostic (fb), L_etc_getmasterdiagnostic (fb) ( 144) – Lenze EtherCAT Controller-based Automation User Manual
Page 144: 9function library l_iodrvethercat.lib
9
Function library L_IODrvEtherCAT.lib
9.4
Diagnostic Interface
144
Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.4.3
L_ETC_GetMasterDiagnostic (FB)
When called, this function block returns a structure with diagnostic information at the oDiagnostic
).
The processing of the POU requires some microseconds (μs).
Visualisation: VISU_L_ETC_GetMasterDiagnostic
Inputs (VAR_INPUT)
Outputs (VAR_OUTPUT)
L_ETC_GetMasterDiagnostic
BOOL xReset
xDone BOOL
xBusy BOOL
xError BOOL
eErrorCode L_ETC_ERRORCODE
oDiagnostic L_ETC_DIAGNOSTIC
Identifier/data type
Meaning/possible settings
xReset
BOOL
A positive edge (TRUE) resets the error counter of the output structure oDiagnostic.
(Exception "Frame Lost Counter")
Identifier/data type
Meaning/possible settings
xDone
BOOL
• TRUE: An action has been executed successfully.
• FALSE: No action active / action is still being executed.
xBusy
BOOL
• TRUE: An action is currently being executed.
• FALSE: No action active
xError
BOOL
• TRUE: An error has occurred.
• FALSE: No error
eErrorCode
L_ETC_ERRORCODE
Error code of the incorrectly executed action (xError = TRUE).
General error codes (L_ETC_ERRORCODE) ( 183)
oDiagnostic
L_ETC_DIAGNOSTIC
Diagnostic information of the
when the function block is called.
• The output oDiagnostic.xDC_InSync is set (TRUE) if the DC master and all DC
slaves have been synchronised.