3 sdo abort codes, Sdo abort codes ( 195), Sdo abort codes – Lenze EtherCAT Controller-based Automation User Manual
Page 195: 12 diagnostics
Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17
195
12
Diagnostics
12.6
System error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.6.3
SDO abort codes
The abort codes are relevant for ...
• the eErrorCode output in some function blocks of the
Function library L_IODrvEtherCAT.lib
;
• SDO read/write error messages, cause by SDO queries from the system (e.g. initialisation code
or SDO queries from the engineering tool).
Error number
[hex]
Description
0x00000000
No error
0x05030000
The status of the toggle bit has not changed.
0x05040000
SDO protocol time-out
0x05040001
Invalid or unknown specification symbol for the client/server command
0x05040002
Invalid block size (only in "Block mode")
0x05040003
Invalid sequence number (only in "Block mode")
0x05040004
CRC error (only in "Block mode")
0x05040005
Not enough space in the main memory
0x06010000
Access to object not supported
0x06010001
Read access to a write-protected object
0x06010002
Write access to a write-protected object
0x06020000
An object does not exist in the object directory
0x06040041
An object cannot be mapped into the PDO
0x06040042
The number and/or length of the objects mapped would exceed the PDO length
0x06040043
General parameter incompatibility
0x06040047
General internal device incompatibility
0x06060000
Access has failed due to a fault in the hardware
0x06070010
The data type or the parameter length does not correspond
0x06070012
Incorrect data type (The parameter length is too large)
0x06070013
Incorrect data type (The parameter length is too small)
0x06090011
A subindex is not available
0x06090030
The value range for parameters is too great (only for write access)
0x06090031
The parameter value is too high
0x06090032
The parameter value is too low
0x06090036
The maximum value is lower than the minimum value
0x08000000
General error
0x08000020
Data cannot be transferred/saved to the application.
0x08000021
Data cannot be transferred/saved to the application because of local control.
0x08000022
Due to the current device state, data cannot be transferred to the application or stored in the
application
0x08000023
The dynamic object directory generation has failed, or no object directory is available