Function library L_IODrvEtherCAT.lib
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
The function blocks of the function library L_IODrvEtherCAT.lib have inputs and outputs for ...
• activation of the POU;
• display of the current POU state;
• output of error messages.
Input/output
Data type
Action
xExecute
BOOL
In the case of a positive edge (TRUE), the function block is executed.
xAbort
BOOL
The xAbort input for aborting requested services is currently not supported
in the Lenze R3.x control technology.
xDone
BOOL
If a function block has been executed, xDone is set to TRUE and xBusy is set
to FALSE.
• If xExecute has been reset, xDone is only active during the function block
call.
• If xExecute = TRUE, then xDone = TRUE as long as xExecute is reset.
xBusy
BOOL
As long as a function block is executed, xBusy is TRUE and xDone is FALSE.
xError
BOOL
If an error has occurred, bError is set to TRUE.
• In the eErrorCode output, the error code is shown. The error code is an
enumeration of the L_ETC_ERRORCODE type.
• By implementing the error code as enumeration, an error is shown as a
string in the online mode.
General error codes (L_ETC_ERRORCODE) ( 183)
xAborted
BOOL
The xAborted output for aborting requested services is currently not
supported in the Lenze R3.x control technology.