12 diagnostics, 6 system error messages 186 – Lenze EtherCAT Controller-based Automation User Manual
Page 186
12
Diagnostics
12.6
System error messages
186
Lenze · Controller-based Automation · EtherCAT® Communication Manual · DMS 6.4 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x9811005C
ETC_E_SDO_ABORTCODE_DICTIONARY
The dynamic object directory generation has failed, or no object directory is
available
Abort code 0x08000023
0x9811005D
ETC_E_SDO_ABORTCODE_UNKNOWN
Unknown internal slave error
0x98110060
ETC_E_FOE_ERRCODE_NOTDEFINED
Manufacturer-specific FoE error
0x98110061
ETC_E_FOE_ERRCODE_NOTFOUND
Not found
0x98110062
ETC_E_FOE_ERRCODE_ACCESS
Access denied
0x98110063
ETC_E_FOE_ERRCODE_DISKFULL
Memory (floppy disk/hard disk) is full.
0x98110064
ETC_E_FOE_ERRCODE_ILLEGAL
Invalid/impermissible
0x98110065
ETC_E_FOE_ERRCODE_PACKENO
Wrong package number
0x98110066
ETC_E_FOE_ERRCODE_EXISTS
Already available
0x98110067
ETC_E_FOE_ERRCODE_NOUSER
User/consumer is missing.
0x98110068
ETC_E_FOE_ERRCODE_BOOTSTRAPONLY
Only bootstrap state
0x98110069
ETC_E_FOE_ERRCODE_NOTINBOOTSTRAP
No bootstrap state
0x9811006A
ETC_E_FOE_ERRCODE_INVALIDPASSWORD
No required access authorisation
0x9811006B
ETC_E_FOE_ERRCODE_PROGERROR
Program error
0x98110070
ETC_E_CFGFILENOTFOUND
The master configuration has not been found.
0x98110071
ETC_E_EEPROMREADERROR
Command error during EEPROM upload
0x98110072
ETC_E_EEPROMWRITEERROR
Command error during EEPROM download
0x98110073
ETC_E_XML_CYCCMDS_SIZEMISMATCH
The cyclical command has a wrong size or is too long.
Internal error. Please contact Lenze.
0x98110074
ETC_E_XML_INVALID_INP_OFF
Invalid input offset in cyclical command
Internal error. Please contact Lenze.
0x98110075
ETC_E_XML_INVALID_OUT_OFF
Invalid output offset in cyclical command
Internal error. Please contact Lenze.
0x98110076
ETC_E_PORTCLOSE
Closing of the port failed.
Internal error. Please contact Lenze.
0x98110077
ETC_E_PORTOPEN
Opening of the port failed.
Internal error. Please contact Lenze.
0x98110078
ETC_E_SOE_ERRORCODE_INVALID_ACCESS
Impermissible access to element 0
Is not supported.
0x98110079
ETC_E_SOE_ERRORCODE_NOT_EXIST
Nonexistent
Is not supported.
0x9811007a
ETC_E_SOE_ERRORCODE_INVL_ACC_ELEM1
Impermissible access to element 1
Is not supported.
0x9811007b
ETC_E_SOE_ERRORCODE_NAME_NOT_EXIST
The name is not available.
Is not supported.
0x9811007c
ETC_E_SOE_ERRORCODE_NAME_UNDERSIZE
The name is too short for transmission.
Is not supported.
0x9811007d
ETC_E_SOE_ERRORCODE_NAME_OVERSIZE
The name is too short for transmission.
Is not supported.
0x9811007e
ETC_E_SOE_ERRORCODE_NAME_UNCHANGE
The name cannot be changed.
Is not supported.
0x9811007f
ETC_E_SOE_ERRORCODE_NAME_WR_PROT
The name is currently write-protected.
Is not supported.
0x98110080
ETC_E_SOE_ERRORCODE_UNDERS_TRANS
The attribute is too small for transmission.
Is not supported.
0x98110081
ETC_E_SOE_ERRORCODE_OVERS_TRANS
The attribute is too big for transmission.
Is not supported.
0x98110082
ETC_E_SOE_ERRORCODE_ATTR_UNCHANGE
The attribute cannot be changed.
Is not supported.
0x98110083
ETC_E_SOE_ERRORCODE_ATTR_WR_PROT
The attribute is currently write-protected.
Is not supported.
0x98110084
ETC_E_SOE_ERRORCODE_UNIT_NOT_EXIST
The unit is not available.
Is not supported.
0x98110085
ETC_E_SOE_ERRORCODE_UNIT_UNDERSIZE
The unit is too small for transmission.
Is not supported.
0x98110086
ETC_E_SOE_ERRORCODE_UNIT_OVERSIZE
The unit is too big for transmission.
Is not supported.
Error no.
[hex]
Designation
Description