_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x98110037
ETC_E_EVAL_VIOLATION
The number of slaves indicated in the XML file is too large for the evaluation
version of the master.
Internal error. Please contact Lenze.
0x98110038
ETC_E_EVAL_EXPIRED
The evaluation time has expired. The fieldbus is stopped.
Internal error. Please contact Lenze.
0x98110040
ETC_E_SDO_ABORTCODE_TOGGLE
The status of the toggle bit has not changed.
Abort code 0x05030000
0x98110041
ETC_E_SDO_ABORTCODE_TIMEOUT
SDO protocol time-out
Abort code 0x05040000
0x98110042
ETC_E_SDO_ABORTCODE_CCS_SCS
Invalid or unknown specification symbol for the client/server command
Abort code 0x05040001
0x98110043
ETC_E_SDO_ABORTCODE_BLK_SIZE
Invalid block size (only in "Block mode")
Abort code 0x05040002
0x98110044
ETC_E_SDO_ABORTCODE_SEQNO
Invalid sequence number (only in "Block mode")
Abort code 0x05040003
0x98110045
ETC_E_SDO_ABORTCODE_CRC
CRC error (only in "Block mode")
Abort code 0x05040004
0x98110046
ETC_E_SDO_ABORTCODE_MEMORY
Not enough space in the main memory
Abort code 0x05040005
0x98110047
ETC_E_SDO_ABORTCODE_ACCESS
Access to object not supported
Abort code 0x06010000
0x98110048
ETC_E_SDO_ABORTCODE_WRITEONLY
Read access to a write-protected object
Abort code 0x06010001
0x98110049
ETC_E_SDO_ABORTCODE_READONLY
Write access to a write-protected object
Abort code 0x06010002
0x9811004A
ETC_E_SDO_ABORTCODE_INDEX
An object does not exist in the object directory
Abort code 0x06020000
0x9811004B
ETC_E_SDO_ABORTCODE_PDO_MAP
An object cannot be mapped into the PDO
Abort code 0x06040041
0x9811004C
ETC_E_SDO_ABORTCODE_PDO_LEN
The number and/or length of the objects mapped would exceed the PDO length
Abort code 0x06040042
0x9811004D
ETC_E_SDO_ABORTCODE_P_INCOMP
General parameter incompatibility
Abort code 0x06040043
0x9811004E
ETC_E_SDO_ABORTCODE_I_INCOMP
General internal device incompatibility
Abort code 0x06040047
0x9811004F
ETC_E_SDO_ABORTCODE_HARDWARE
Access has failed due to a fault in the hardware
Abort code 0x06060000
0x98110050
ETC_E_SDO_ABORTCODE_DATA_SIZE
The data type or the parameter length does not correspond
Abort code 0x06070010
0x98110051
ETC_E_SDO_ABORTCODE_DATA_SIZE1
Incorrect data type (The parameter length is too large)
Abort code 0x06070012
0x98110052
ETC_E_SDO_ABORTCODE_DATA_SIZE2
Wrong data type (parameter length is too small).
Abort code 0x06070013
0x98110053
ETC_E_SDO_ABORTCODE_OFFSET
A subindex is not available
Abort code 0x06090011
0x98110054
ETC_E_SDO_ABORTCODE_DATA_RANGE
The value range for parameters is too great (only for write access)
Abort code 0x06090030
0x98110055
ETC_E_SDO_ABORTCODE_DATA_RANGE1
The parameter value is too high
Abort code 0x06090031
0x98110056
ETC_E_SDO_ABORTCODE_DATA_RANGE2
The parameter value is too low
Abort code 0x06090032
0x98110057
ETC_E_SDO_ABORTCODE_MINMAX
The maximum value is lower than the minimum value
Abort code 0x06090036
0x98110058
ETC_E_SDO_ABORTCODE_GENERAL
General error
Abort code 0x08000000
0x98110059
ETC_E_SDO_ABORTCODE_TRANSFER
Data cannot be transferred/saved to the application.
Abort code 0x08000020
0x9811005A
ETC_E_SDO_ABORTCODE_TRANSFER1
Data cannot be transferred/saved to the application because of local control.
Abort code 0x08000021
0x9811005B
ETC_E_SDO_ABORTCODE_TRANSFER2
Due to the current device state, data cannot be transferred to the application or
stored in the application
Abort code 0x08000022
Error no.
[hex]
Designation
Description