10 specifications – SkyTrak 6036 Service Manual User Manual
Page 85
Model 6036 S/N 9B0499 and Before
7-5
Section 7.
Transmission
7.10 SPECIFICATIONS
Filter Capacity
Converter:
Outlet oil temperature
1 quart (0,95 liter)
180 to 200 °F (82 to 93 °C) Transmission in Neutral.
Outlet pressure
25 psi (1,72 bar) minimum pressure at 2000 rpm
engine speed
70 psi (4,82 bar) outlet pressure with engine operating at
no-load governed speed.
Oil Filtration
Full flow oil filter safety bypass. Strainer screen in sump
at bottom of transmission case.
Clutch Pressure
180 to 220 psi (12,40 to 15,16 bar) with:
• park lock set (Never use service brakes)
• oil temperature at 80 to 200
o
F (82 - 93
o
C
)
• engine at idle (400 to 600 rpm)
Shift thru direction and speed clutches. All clutch pres-
sure must be equal within 5 psi (0,34 bar). If clutch pres-
sure varies in any one clutch by more than 5 psi (0,34
bar), repair the clutch.
Tractor Fluid
John Deere J20 A
Detroit Diesel C-3, C-2
Ford Tractor M2C134B
White Farm UTHF Q1766, Q1722
System Capacity (inc. filter and oil cooler)
4.3 gallons (16,3 liter)
Controls
Forward and Reverse is Manual
Speed Selection is Manual
Clutch Type
Multiple discs, hydraulically actuated, spring released,
automatic wear compensated, and nonadjustable. Oil
cooled and lubricated.
Inner Disc–Friction
Outer Disc–Steel