Center Position

When the auxiliary control lever is placed in the
center or neutral position, the directional control
valve spool is positioned so that supply pressure is
applied through ports F to C, Fig. 9.8, to the return
filter and reservoir. If the filter becomes clogged,
hydraulic oil will bypass the filter when the pres-
sure reaches 10 to 15 psi

(0,7 to 1,03 bar).

Forward Position

When the auxiliary control lever is placed in the
forward position, the directional control valve spool
is positioned so that pump applied pressure is
directed through ports E to A, Fig. 9.8, to the
female auxiliary quick connect coupler. Return
pressure is directed through ports B to D to the
return filter and reservoir. If the filter becomes
clogged, hydraulic oil will bypass the filter when
the pressure reaches 10 to 15 psi (0,7 to 1,03
bar).

FEMALE

MALE

TO AUXILIARY

ATTACHMENTS

MAIN CONTROL

VALVE

DIRECTIONAL CONTROL VALVE

POSITIONS

RESERVOIR

TANDEM

PUMP

RETURN

FILTER

STRAINER

30

GPM

15

GPM

A B C A B C A B C

FORWARD

D E F D E F D E F

CENTER

Fig. 9.8 Optional Auxiliary Circuit

TO FRAME TILT

CYLINDER

TO GRILLE TILT AND

SLAVE CYLINDERS

TO BOOM EXTEND/

RETRACT CYLINDER

TO BOOM HOIST

CYLINDERS

BACKWARD

FORWARD

BACKWARD

0-4000 psi

PRESSURE

GAUGE

MA0491